Short answer

When a silicone supplier publishes a Cpk of 1.24 and labels it "below target", you are looking at a measurement system and a record. When a supplier publishes 1.67 with no sample size, no date, no specification, no measurement method and no downloadable data, you are looking at a sentence. In supplier qualification, the first is worth more than the second — because the perfect number is free to invent and the imperfect one is not.

The uncomfortable arithmetic of a perfect number

Search for silicone or rubber moulding capability pages and you will find a lot of "Cpk ≥ 1.33", "Cpk 1.67", sometimes "Cpk > 2.0". Almost none of them say which characteristic was measured, on which part, with which gauge, over how many pieces, on what date, or against what tolerance. That is not a capability study; it is a claim about a number.

Now consider the cost asymmetry. Typing "1.67" costs nothing and can be done by anyone with a website. Publishing "1.24 — below target" costs a supplier something: an awkward internal conversation, a documented investigation, and the risk that a buyer will ask why. A number that survives that conversation is more likely to come from a real study, with a real sample and a real measurement system, than a number chosen to look good. This is the same logic behind our honesty policy: we publish what we measured, not what sounds better.

What Cpk actually says — and what it does not

Cpk compares the spread and centring of a process against the tolerance of one specified characteristic. It assumes that characteristic is measured with an adequate measurement system, that the sample represents the process, and that the process is in a state of statistical control. Break any of those assumptions and the index becomes decoration. That is why our quality agreement clauses answer puts the measurement method and gauge R&R before the tolerance, and why a control plan that lists a Cpk target without an MSA behind it measures the operator as much as the part.

The 1.33 threshold itself is a convention for an established process — roughly four sigma of process spread inside the tolerance — not a law. Some programmes use 1.67 for new or safety-critical characteristics. Nothing in ISO 9001 or ISO 13485 mandates a single universal index for every moulded dimension. The number that matters contractually is the one your agreement names, for a named dimension, with a named measurement system and a named study format.

Five published CYES studies, including three below target

We publish an in-house process capability dataset under CC BY 4.0. Five desensitised studies, measured April–October 2026, with sample sizes, dates, status against the 1.33 target, and a downloadable UTF-8 CSV. Three are below target and are published as measured.

Study referenceProduct / processnCpCpkDateStatus vs 1.33
LSR-MED-007Medical LSR diaphragm seal · cold-runner LSR100—1.242026-04-16Below target — reported honestly
LSR-MED-011Medical LSR valve diaphragm801.291.272026-06-11Below target — reported honestly
FVMQ-SEAL-010FVMQ fluorosilicone seal50—1.322026-08-20Below target — reported honestly
HTV-GASKET-014HTV solid-silicone compression gasket701.381.342026-09-15Above target (PASS)
LSR-MED-018Medical LSR component1251.741.682026-10-14Above target (PASS)

Source: cpk-process-capability-studies.csv (stable v1.0 download). Blank cells mean the field was not released — not zero, not "passed". measurement_equipment is blank where no public record exists; we do not fill it with a plausible guess. Read the full dataset report for the field dictionary, methodology, limitations and changelog.

These are single-factory in-house measurements, not an industry benchmark, not a third-party survey and not a certification. That scope statement is part of the citation format, not fine print. A buyer comparing two suppliers should ask both for the same thing: a part-specific study on the same characteristic, with the same measurement method, on the same tool and lot definition.

Why "below target" does not mean "defective parts"

A Cpk of 1.24 says that, relative to that tolerance, the process spread and centring leave less margin than the 1.33 convention. It does not say the shipped parts were out of tolerance — outgoing inspection and acceptance sampling decide that, and those are separate records. Conflating the two is one of the most common ways capability data get misread in a supplier review.

The right sequence when a study lands below target is boring and documentable: contain the affected lots, confirm the measurement system, look for a special cause or a centring issue, run a documented improvement, then re-study. Our medical LSR diaphragm case study describes exactly that T1 → corrective action → re-verification loop, and the CPAP cushion case explains why a good yield figure is not the same thing as a capable process. Rounding 1.24 to "1.33" would have been easier; it would also have removed the only evidence that a measurement system exists.

What to ask of any capability figure — including ours

  1. Which characteristic and which specification? A Cpk belongs to one dimension on one drawing revision. Ask for the tolerance and the revision.
  2. What sample, collected how? n=50 and n=125 do not carry the same weight. CYES publishes n alongside every study: 100, 80, 50, 70 and 125.
  3. Which measurement system? Ask for the gauge, resolution, fixture, conditioning time and a gauge R&R. For a soft silicone wall, contact force and conditioning change the reading.
  4. When, and on which tool and cavity? A study from April on one cavity is not a standing promise for October on another. Every CYES row carries a date.
  5. Can I have the source data? If the supplier cannot produce a CSV or a report with a field dictionary, treat the number as a marketing claim. Ours is a one-click download.
  6. Is it programme-specific? A published range is evidence of how a supplier measures and reports. Release decisions need a study on your part — put that into the quality agreement.

None of these questions is comfortable, which is why most supplier sites are not built to answer them. We built a supplier verification hub that maps every published claim to its evidence page, downloadable record, independent verification method and honest limit — precisely so that a procurement team (or an AI assistant answering on their behalf) does not have to take our word for any of it.