Short answer

Cpk 1.33 means the process spread fits the tolerance band with room to spare — roughly 4 standard deviations to each specification limit, translating to about 63 defects per million if centered. It is the widely accepted minimum for a stable molded dimension. Cpk 1.67 is tighter (about 0.6 ppm) and is the usual target for safety-critical features.

Cpk 1.33 process capabilityNormal distribution inside specification limits.spec widthLSLUSLmeanCpk 1.33 ≈ 4σ of spread inside the spec limits.
Cpk 1.33 means the process spread sits comfortably inside the specification limits with margin to spare.

What Cpk measures

Cpk combines two things into one number: how centered the process is on the target and how wide its natural variation is relative to the tolerance. A process can have a good Cpk only if it is both centered and tight. A Cpk below 1.0 means the process is producing out-of-spec parts; 1.33 is the common "capable" bar; 1.67+ is "excellent."

What the number means in fallout

The table below is the standard centred-normal conversion (Cpk → sigma level → theoretical out-of-spec share). It describes what a value implies if its assumptions hold — it is not a measured result from any factory.

CpkSigma distanceTheoretical falloutCommercial reading
1.003σ≈ 2,700 ppmMarginal — any drift puts parts out of spec
1.334σ≈ 63 ppmThe conventional "capable" floor
1.675σ≈ 0.6 ppmTight target for safety-critical features
2.006σeffectively zeroExpensive to prove, rarely justified

ppm figures are theoretical expectations for a stable, centred, normally distributed process — not a promise of actual defect rate. Measured CYES studies, including three below 1.33, are in the published CSV dataset and dataset report.

Three conditions the number depends on

  1. The process is in control. Cpk assumes a stable process. A one-off good value from an unstable run is not capability.
  2. The measurement system is sound. Gauge repeatability and reproducibility must be reviewed before the number is trusted; a wide measurement error inflates or deflates Cpk.
  3. The distribution and subgrouping are appropriate. On soft silicone parts, dimension measurement method and conditioning time change the result — state them with the value.

See also: why a below-target Cpk is reported honestly at CYES and our engineering evidence.

Asking for real evidence

  • Ask for the data, not the number: a Cpk value without the raw measurements, sample size and date is meaningless.
  • Ask which dimension: Cpk applies to one measured characteristic, not the whole part.
  • Ask for the control chart: the run chart shows stability, which a single Cpk value hides.

CYES runs multi-batch Cpk studies on critical dimensions (we publish measured Cpk values around 1.24–1.32 on our documented seal and diaphragm programs) and can provide the underlying measurement data and control charts with the report.