CYES Precision Engineering — Medical LSR, Automotive Seals, Electronics Parts & High-Precision Tooling

An engineering-driven partner for industrial, medical, automotive and electronics buyers who need silicone parts that meet specification — liquid silicone rubber (LSR) injection, tight-tolerance seals and gaskets, engineering-plastic overmolding, and in-house high-precision mold making. Every precision claim is tied to a measured study or a defined feature, not a catalog headline. Our benchmark is from tooling precision to proven part capability — we report not only how precisely we machine a mold, but how a finished part performs against its specification.

For Engineers & Procurement

Precision That Is Measured, Not Assumed

CYES Precision Engineering is the division for parts where a dimension, a seal or a process capability actually decides whether the product works. We serve engineers and sourcing teams in medical, automotive, electronics and industrial equipment.

What separates this division from a general molding shop: in-house MAKINO 24,000 RPM CNC and EDM tooling, documented process-capability studies (Cpk), an ISO Class 7 cleanroom for medical LSR, and ISO 9001 / ISO 13485 quality systems.

CNC machining centers for high-precision silicone mold cavities
Four Capability Areas

Where Precision Engineering Delivers

Medical LSR Components

Liquid silicone injection for seals, diaphragms, valves and device components in an ISO Class 7 cleanroom, with documented Cpk and ISO 13485 traceability.

Automotive Seals & Gaskets

Seals, gaskets and boots that hold under temperature, fluid and duty cycles — molded to defined tolerances with material test data.

Electronics Silicone Parts

Keypads, gaskets, feet and protective parts with consistent Shore A hardness, color and dimensional repeatability.

High-Precision Mold Making

In-house CNC and EDM tooling with cavity machining to ±0.008 mm on specified features — no outsourced mold markup.

Measured Capability

Precision, With the Conditions Stated

These are the numbers we publish — and the conditions that define them, so you never mistake a specific-feature capability for a blanket tolerance.

MetricValueApplies to (condition)
EDM fine-feature machining±0.003 mmPrecision inserts, micro sealing features, narrow ribs/grooves
LSR shut-off / gate features±0.005 mmCold-runner sealing and gate features, not all dimensions
CNC mold-cavity machining±0.008 mmSpecified cavity features (CNC)
Finished-part critical dimension±0.02 mmMedical LSR diaphragm seal (study LSR-MED-007, Cpk 1.24)
General finished-part tolerance±0.1–0.3 mmSize-dependent; subject to design and process
Process capabilityCpk 1.24–1.68Five measured studies — LSR-MED-007, FVMQ-SEAL-010, LSR-MED-011, HTV-GASKET-014, LSR-MED-018
Outgoing defect rate<0.1% (<1,000 PPM)Defective units ÷ units shipped, measured at the OQC release gate (rolling 6-month)
Customer complaint rate<500 PPMCustomer complaints per million units shipped (rolling 6-month)
LSR cold-runner mold life500,000+ shotsS136 / NAK80 steel, cold-runner LSR tooling — planned and validated

Every precision figure above is tied to a defined feature, study or condition — not a blanket promise. Browse the Precision Manufacturing Evidence Center →

Materials & Process at a Glance

Beyond dimensional precision, here are the material, hardness, temperature and cleanroom capabilities — each with the condition that defines it.

SpecificationCapabilityNotes / condition
Material optionsMedical-grade LSR · HTV solid silicone · FVMQ fluorosiliconePlatinum-cured LSR for medical (platinum residue <5 ppm after controlled post-cure); FVMQ for oil & fuel resistance
Hardness rangeShore A 10–90Measured with LX-A durometer
Service temperature-40 to 230 °C (silicone) · -20 to +250 °C (FVMQ)FVMQ rated "Excellent" for oil & fuel; FVMQ typical TR10 -58 °C
CleanroomISO Class 7 (ISO 14644-1)Medical-grade LSR molding
In-house testingCMM (HEXAGON Global S / ZEISS SPECTRUM / ZEISS CONTURA) · tensile tester · durometer · CNC video measuring machineTied to the measurement basis below

Material, hardness, temperature and cleanroom figures are capabilities with their conditions stated — see the tolerance table above for dimensional precision and the measurement basis below for how each is verified.

Measurement Basis — How Each Tolerance Is Verified

Each tolerance above is tied to a defined instrument class, measurement method, sampling plan and an internal inspection report — so the number can be audited rather than assumed.

FeatureInstrument (max. permissible error)Method & standardSampling planReport no.
EDM fine-feature ±0.003 mm High-accuracy CMM (MPE ≤1 µm), or gauge blocks + lever comparator, or toolmaker's microscope (reflected light, ≤1 µm class) ISO 10360-2 (CMM verification), ISO 14253-1 (uncertainty-based conformance), ISO 1 (20 °C reference temperature) 100% first-article measurement of critical features; 3 re-fixtures per feature for repeatability; re-inspection n=3 per cavity (first / middle / last) QC-MOLD-EDM-2026-10-21
LSR shut-off / gate ±0.005 mm Vision measuring machine (MPE ≤2 µm, calibrated to JJF 1318), or CMM with vision head (ISO 10360-7) ISO 10360-7 (vision probing head), JJF 1318-2011 (vision instrument calibration), ISO 14253-1 Every gate measured at mold acceptance with 3 re-fixtures; 3-shot sampling during injection validation QC-MOLD-GATE-2026-10-22
CNC mold-cavity ±0.008 mm CMM (MPE ≤2.5 µm) or vision machine (MPE ≤3 µm) ISO 230-2, ISO 10360-2, ISO 14253-1; finished parts to ISO 3302-1 (rubber tolerance class M) First-article full measurement; re-inspection n=3, one piece per cavity QC-MOLD-CNC-2026-08-20

Instrument figures are maximum permissible error (MPE) — an instrument specification, not the measured uncertainty of a specific result. Measured measurement uncertainty U (k=2) and the resulting test-uncertainty-ratio class (TUR ≥ 3 baseline / ≥ 10 tightened) are available on request under NDA; we do not publish an uncertainty figure we have not verified. Report numbers reference internal QC inspection records and are shared with qualified buyers.

Verified Quality

Quality Systems Behind the Precision

ISO 9001:2015

Certified quality management (ZPIC, cert no. 61120Q012, valid 10 Jul 2026 to 9 Jul 2027).

ISO 13485

Medical-device quality system (cert no. 04724Q10000602, valid 2024-08-23 to 2027-08-22).

ISO Class 7 Cleanroom

Designated cleanroom molding and packing for medical LSR, verified by third-party testing.

See the full certification scope and scanned certificates: Certifications & Compliance →

Documented Cases

Precision Projects, With the Numbers

Medical LSR Diaphragm Seal

From drawing to mass production: ±0.02 mm critical dimension, Cpk 1.24, ISO Class 7 production — a fully documented engineering case.

Read the case

CPAP Mask Cushion Seal

100,000 units per month at ≥99% first-pass yield, Shore 40A medical-grade LSR, multi-cavity cold-runner tooling (client anonymized under NDA).

Read the case
Common Questions

Precision & Tolerance FAQ

We publish three distinct machining tolerances, each tied to a specific feature and condition — EDM fine-feature machining at ±0.003 mm (precision inserts, micro sealing features, narrow ribs), LSR shut-off and gate features at ±0.005 mm, and CNC mold-cavity machining at ±0.008 mm. Each figure states the feature it applies to and the measurement method behind it, so a single number is never mistaken for a blanket tolerance.
A tolerance figure is only meaningful with its definition. We state ±0.008 mm as a measured CNC cavity tolerance, and separately publish ±0.003 mm for EDM fine features and ±0.005 mm for LSR shut-off and gate features — each with the instrument, standard and sampling plan behind it. We ask every supplier the same question: does the figure refer to machine positioning accuracy, a process tolerance, or the measured tolerance of the finished cavity? Without that definition, a smaller number is not a stronger claim.
Yes. We publish five process-capability studies with sample sizes, measured characteristics, test dates and actual Cpk results (Cpk 1.24–1.68). We report results honestly — including a study below the common 1.33 target — rather than selecting only the highest value. Full details are on our engineering evidence page.

Start a Precision Project

Share your drawing, sample or specification. Our engineering team reviews DFM, material and process capability — then gives you an honest go/no-go and a preliminary quote.

Request a Quote