Delta E (ΔE) is the numerical distance between two colors — a ΔE under 1 is invisible, under 2 is barely noticeable, and under 3 is a common commercial tolerance. For silicone, the target is set by matching a Pantone or a physical master under D65 lighting, and the pigment dose must be adjusted because silicone changes color slightly as it cures.
What Delta E means in practice
| ΔE | Perception | Use |
|---|---|---|
| < 1 | Not perceptible | Critical brand color |
| 1–2 | Barely perceptible | Strict match |
| 2–3 | Acceptable | Standard commercial |
| > 3 | Clearly different | Not acceptable for a match |
How silicone color is controlled
We match color by dosing pigment into the compound and measuring the cured plaque against the master with a spectrophotometer under D65 light. Because silicone shifts subtly during cure and post-cure, we color-match on the cured part, not the raw compound. For translucent or matte parts we also match finish, since surface texture changes perceived color as much as the pigment does.