AQL (Acceptable Quality Limit) defines how many defects you will tolerate in a sampled lot. For molded silicone parts, a common spec is AQL 1.0 for critical defects, 2.5 for major and 4.0 for minor, inspected per ISO 2859-1. Putting AQL in the PO turns a vague "good quality" into a measurable, enforceable standard.
What AQL actually means
AQL is the worst tolerable average quality level, stated as a percentage of defective units. AQL 2.5 means a process that averages 2.5% defective is still acceptable — a higher AQL number is looser, not tighter. The sampling plan (sample size and accept/reject numbers) comes from ISO 2859-1 (ANSI/ASQ Z1.4), which ties sample size to lot size and inspection level.
A practical spec
- Critical defects (safety, leaks): AQL 0.4–1.0, sometimes 100% inspection.
- Major defects (function, dimensions): AQL 1.0–2.5.
- Minor defects (cosmetic): AQL 2.5–4.0.
For most consumer silicone products we recommend AQL 2.5 major / 4.0 minor as a starting point, tightening to 1.0 on the sealing or functional surfaces. Write it as "inspection per ISO 2859-1, general inspection level II, AQL 1.0 critical / 2.5 major / 4.0 minor."