A mold wears by shots, not by calendar, so maintenance should be scheduled by cycle count. A light inspection and vent cleaning every 10,000–50,000 shots and a full preventive overhaul before the tool shows visible wear keeps tolerance and finish stable — and extends a steel tool’s life past 500,000 shots.
Why shots, not months
Two identical tools can run very different volumes in a month, so a calendar schedule either over-maintains a lightly used tool or under-maintains a hot one. Tracking the shot counter — the number of molding cycles — ties maintenance to actual wear.
A working schedule
| Interval | Action |
|---|---|
| Every run / shift | Clean flash and vents, check for build-up |
| 10,000–50,000 shots | Inspect shut-off edges, re-clean vents, check ejector pins |
| 100,000+ shots | Re-polish or re-cut worn shut-offs, verify cavity dimensions |
| End of life | Full refurbish or retire; plan the replacement tool before it fails |
A maintained tool also protects tolerance: worn shut-off edges are the number-one cause of flash creeping back and dimensions drifting. We track shot counts per tool and flag a tool for inspection before the part goes out of spec — which is why our documented tools hold dimensions and finish far longer than neglected ones.