Short answer

Mold life is set by steel, material and maintenance. A soft or prototype mold lasts only 300–500 shots; a hardened compression tool in P20 or better runs 100,000–300,000 shots; a well-maintained LSR steel tool can run 500,000 to 1,000,000+ shots. Abrasive fillers, aggressive cycles and worn shut-offs all shorten life.

Mold life scaleShot life by tool type.Shots before the tool needs rework300–500soft / prototype100k–300kcompression (P20+)500k–1M+LSR steelAbrasive fillers and worn shut-offs shorten life.Harden + maintain the shut-off to extend it.
Soft molds last 300–500 shots, compression tools 100k–300k, LSR steel 500k–1M+ — set by steel, material and maintenance.

What wears a mold

A silicone tool wears on the shut-off edges that control flash, the vents, and any sliding or moving features. Abrasive or high-filler compounds accelerate the wear; a clean platinum-cure LSR is relatively gentle. Cycle rate matters too — more shots per hour is more wear per hour.

Life by tool type

Tool typeTypical life
Soft / prototype mold300–500 shots
Compression tool (P20+)100,000–300,000 shots
LSR steel tool500,000–1,000,000+ shots

How to extend it

  • Harden and polish the shut-off surfaces — that is where flash begins.
  • Follow a maintenance schedule (clean vents, re-lube slides, check shut-off).
  • Flag abrasive fillers at DFM so the steel is specified for them.