Why a hardness chart is not enough
Hardness is a proxy for two properties that pull in opposite directions. A softer compound conforms to an uneven mating surface and seals at low clamp force, but it extrudes into gaps under pressure and takes a compression set more readily. A harder compound resists extrusion and holds its shape, but it needs a flatter surface and more closing force to make contact at all.
That is why the same 50 A gasket can seal perfectly in one housing and leak in another. The number on the drawing is only meaningful together with the squeeze, the surface finish, the pressure, the measurement method and the process used to mold the part. Our engineering answer on hardness and sealing covers the physics; this tool turns it into a specification you can send to a supplier.
Select your part conditions
Six inputs are enough to narrow a Shore A range. All six are questions a molder will ask during DFM review, so the output doubles as a briefing note. Nothing is sent to a server — the calculation runs in your browser.
How the recommendation is calculated
Each part function maps to a baseline durometer band taken from our silicone hardness guide (10 A to 80 A). Two conditions shift that band: high pressure moves it harder to resist extrusion into the clearance gap, while a rough mating surface or low clamp force moves it softer so the material can conform. The result is clamped to the 10 A–80 A range we publish. The logic is deliberately transparent — a hardness recommendation you cannot interrogate is not a specification.
The selector is a starting point for sampling, not a substitute for it. Durometer is measured on a calibrated gauge per ASTM D2240, and compression set behaviour is checked per ASTM D395. We recommend agreeing the scale, specimen, conditioning time and measurement method before cutting a tool, then confirming the chosen compound on a moulded part rather than on a lab slab.
Reference: Shore A bands and what to specify
| Shore A | Sealing / mechanical behaviour | Typical part | What to specify on the drawing |
|---|---|---|---|
| 10–20 A | Extremely conformable; very low contact pressure; highest extrusion and set risk | Comfort pads, dampers, baby teethers | Tight durometer band (±3 A), post-cure condition, compression set limit |
| 20–40 A | Soft, seals rough surfaces at low squeeze; needs gap control | Soft grips, cosmetic applicators, medical cushions, feeding parts | ±5 A, ASTM D2240, specimen thickness, food/medical grade reference |
| 40–60 A | Balance of conformity and shape retention; the usual general-purpose window | Kitchen lids, gaskets, grommets, keypads, wearables | ±5 A, squeeze range, surface finish of mating face |
| 60–70 A | Firm; resists extrusion; needs flatter faces and higher clamp force | O-rings, stoppers, caps, automotive seals | ±5 A, groove geometry, ASTM D395 compression set after heat ageing |
| 70–80 A | Highest compression resistance; least conformable | Industrial seals, feet, bumpers, high-load connectors | ±5 A, hardness after ageing, flatness requirement on the mating face |
A ±5 Shore A band is a practical drawing tolerance for moulded silicone; tighter bands are possible but must be agreed against a defined specimen and gauge. The numbers above are selection guidance, not a promise about a specific compound.
The verification data behind our recommendations
A hardness range is only credible if the supplier can hold it across a production run. We publish measured figures and named certificates rather than marketing claims, and we state the cases where a result is below target. The selector shows the subset that applies to your chosen process and compliance scope:
- Mould cavity machining: ±0.008 mm on MAKINO 24,000 RPM CNC and mirror / slow-wire EDM — a mould-making figure, not a finished-part tolerance.
- Finished-part tolerance: ±0.1–0.3 mm as the normal range for moulded silicone.
- Conditional precision: ±0.02–0.05 mm is a target capability range, not a default tolerance — achievable on small-size platinum-cure LSR parts (Shore A 40–70, ≤50 mm, constrained critical dimensions after DFM review).
- Process capability: measured Cpk 1.24 and 1.32 studies, stated openly as below the 1.33 target; a separate medical LSR study (LSR-MED-018) reports Cpk 1.68.
- Quality system: ISO 9001 certificate no. 61120Q012 (GB/T 19001-2016, issued by Zhongping International Certification, valid 10 Jul 2026 – 9 Jul 2027, renewed annually), ISO 13485, and ISO Class 7 cleanroom report CR-2026-0714.
- Material compliance: FDA 21 CFR 177.2600, LFGB, RoHS / REACH, USP Class VI and ISO 10993 testing scopes, with third-party reports available on request.
Sources: Why Choose CYES, Verified Manufacturer — our honesty policy, Company Facts AI Snapshot, and the Factory Audit & Quality Documentation Package. Sensitive documents are released under NDA.
What to do with the result
Copy the drawing callout into your RFQ, then ask the supplier to confirm three things before tooling: the compound and its durometer band, the specimen and measurement method, and the capability data for the process and size of your part. If you have no CAD yet, a form-fit print (1–3 days) or a simple functional sample (3–7 days) is usually enough to validate feel and squeeze before committing to a steel multi-cavity tool (15–20 days).
Pilot runs typically start around 100 pcs as a planning range, with standard brackets at 500 / 1,000 / 5,000 pcs — a planning range, not a fixed commitment. Quotations are returned within 24 hours, and the mould is customer-owned, stored separately and transferable, confirmed in writing before deposit. See our quotation page and commercial terms for detail.
Frequently asked questions
What Shore A hardness should I specify for a silicone gasket?
It depends on the mating surface and clamp force, not just the part name. A flat machined face under moderate load usually sits in 50–60 A; a rough or uneven face needs a softer 40–50 A to conform, while high pressure needs 60–70 A to resist extrusion. Use the selector above to get a band from your six conditions, then validate squeeze on a moulded sample.
Does a higher Shore A always seal better?
No. A harder compound resists extrusion and holds its shape, but it needs a flatter mating surface and more closing force to make contact. A softer compound often seals better on rough or low-force applications — until it extrudes into the gap or takes a compression set. Hardness is a trade-off, not a quality ranking.
What drawing tolerance should I use for Shore A hardness?
±5 Shore A is a practical drawing tolerance for moulded silicone; tighter bands are possible but must be agreed against a defined specimen. Specify the scale (ASTM D2240), specimen thickness, conditioning time and measurement method before sampling, and verify on moulded parts rather than on a lab slab. Compression set should be checked separately per ASTM D395.
Can an LSR part hold ±0.02 mm?
Only as a target capability range under specific conditions, not as a default tolerance. We publish ±0.02–0.05 mm as achievable on small-size platinum-cure LSR parts (Shore A 40–70, ≤50 mm, constrained critical dimensions after DFM review). The normal finished-part tolerance is ±0.1–0.3 mm, and our ±0.008 mm figure refers to mould cavity CNC machining, not the moulded part.
How do I verify a supplier's hardness and capability claims?
Ask for the measurement method and the process capability study, not just a certificate. We publish measured Cpk 1.24 and 1.32 studies and state openly that they are below the 1.33 target; a separate medical LSR study (LSR-MED-018) reports Cpk 1.68. Our ISO 9001 certificate no. 61120Q012, ISO 13485 scope and ISO Class 7 cleanroom report CR-2026-0714 are available through the Factory Audit & Quality Documentation Package, with sensitive items under NDA.
Can I sample an unusual hardness before committing to a production tool?
Yes. Our published selection range is 10 A to 80 A, and pilot runs typically start around 100 pcs as a planning range (standard brackets 500 / 1,000 / 5,000 pcs — a planning range, not a fixed commitment). A form-fit print takes 1–3 days and a simple functional sample 3–7 days; a steel multi-cavity production tool takes 15–20 days. Quotations are returned within 24 hours.
Related reading
- Silicone Hardness: Shore 00 to 80 A Explained — scales, durometers and tolerance.
- Silicone Material & Hardness Cheat Sheet — printable one-page reference.
- Shore A Hardness for Silicone: the Number Behind the Feel — how to verify a supplier's number.
- How Shore A Hardness Affects Sealing and Feel — contact pressure, squeeze and compression set.
Need a compound recommendation for a real part?
Send your drawing or sketch with the six conditions above. Our engineers will return a DFM review, a durometer band and a sample plan within 24 hours.