LFGB §30/31 measures the organic volatiles that can migrate from silicone into food. A passing result requires a platinum-cured, properly post-cured part — and the report should be per batch, not a one-time material certificate.
What the test actually measures
The LFGB §30/31 organic-volatile test (German Food and Feed Code) measures the total organic volatiles a silicone part can release into a food simulant. It is stricter than a simple FDA 21 CFR 177.2600 extraction in practice, because it targets the residual by-products that cause odor and off-taste — the classic sign of an under-cured or peroxide-cured part.
The evidence behind the claim
Standards mean nothing without the certificates and the data behind them. This is the measured record behind our Certification & Standards programs — available for your qualification.
- Certifications: ISO 9001 (61120Q012) and ISO 13485 (04724Q10000602), numbers and scope published — originals under NDA.
- Material compliance: CTI-tested against FDA 21 CFR 177.2600, LFGB §30/31, RoHS and REACH, per batch.
- Process capability (Cpk): five studies — LSR-MED-007 (Cpk 1.24), FVMQ-SEAL-010 (Cpk 1.32), LSR-MED-011 (Cpk 1.27), HTV-GASKET-014 (Cpk 1.34), LSR-MED-018 (Cpk 1.68) — reported against the 1.33 target.
- Cleanroom class: ISO Class 7 (ISO 14644-1:2015), validated with report CR-2026-0714.
- Mold & cavity accuracy: ±0.008 mm CNC, ±0.005 mm LSR, ±0.003 mm mirror-EDM.
See the full engineering evidence page →
What to watch for when you source
Passing is a process result, not a material property: the same compound can pass or fail depending on cure and post-cure. We post-cure every batch 4–6 hours at 200 °C and issue per-batch LFGB §30/31 and FDA reports through CTI. A one-time material certificate is not enough — ask for the report on your finished part, from your actual batch.
| Specification | Typical / range |
|---|---|
| Standard | LFGB §30/31 (Germany) |
| Measures | Total organic volatiles |
| Simulant | Food simulant extraction |
| Related | FDA 21 CFR 177.2600 |
| Pass driver | Platinum cure + post-cure |
| Reporting | Per-batch (we provide) |