Short answer

ASTM D2000 is a shorthand that describes a rubber by heat resistance, oil resistance and physicals. For silicone the common call-outs are FC, FE and GE — each locks down temperature and material requirements so a supplier cannot substitute a cheaper grade.

One line of code replaces a paragraph of specs

ASTM D2000 encodes a material as Type (heat resistance) – Class (oil resistance) – Grade (physical requirements) – suffix codes. Silicone is typically FC, FE or GE (F/G = the temperature letter, C/E = oil-swell class). The suffix letters then add tensile, compression-set and tear requirements. Reading the line correctly tells you whether a quote is actually quoting silicone, or a cheaper EPDM or NBR.

The evidence behind the claim

Material selection lives or dies on data. This is the measured record behind our Material Selection programs — the same data you can request during qualification.

  • Material compliance: third-party tested by CTI against FDA 21 CFR 177.2600, LFGB §30/31, RoHS and REACH, with per-batch reports — so “food grade” or “medical grade” means a documented grade, not a claim.
  • Process capability (Cpk): five documented studies — LSR-MED-007 (Cp 1.31 / Cpk 1.24), FVMQ-SEAL-010 (Cpk 1.32), LSR-MED-011 (Cpk 1.27), HTV-GASKET-014 (Cpk 1.34), LSR-MED-018 (Cpk 1.68) — reported against the 1.33 target.
  • Mold & cavity accuracy: ±0.008 mm CNC, ±0.005 mm LSR shut-off / gate, ±0.003 mm mirror-EDM.
  • Certifications: ISO 9001 (61120Q012) and ISO 13485 (04724Q10000602), numbers and scope published — originals under NDA.
  • Cleanroom: ISO Class 7 per ISO 14644-1:2015 — report CR-2026-0714.

See the full engineering evidence page →

What to watch for when you source

The risk is a supplier that paraphrases instead of certifying — "meets ASTM D2000" with no line call-out and no test data. We state the full call-out and back it with measured physicals, and our compression-set and tolerance control is documented (HTV-GASKET-014 holds Cpk 1.34 on a 2.00 mm wall). If the datasheet does not match the call-out, the quote is not honest.

SpecificationTypical / range
StandardASTM D2000 / SAE J200
Silicone typesFC · FE · GE
What it locksHeat, oil, physicals
SuffixesTensile, comp-set, tear
Substitution riskEPDM / NBR lookalikes
Our practiceFull call-out + measured physicals