DFM Design Checklist
A pre-tooling checklist for buyers and engineers. Run your design past these ten decisions before you pay for steel — each one is where cost, lead time or quality is won or lost.
1 · The ten decisions — check before you cut steel
Run your design past these ten points before tooling. Each one is a place where cost, lead time or quality is won or lost.
- Wall thickness. Keep walls uniform. LSR can fill down to 0.25–0.5 mm; a comfortable working range is 0.5–3 mm. Solid silicone (HCR) suits thicker sections. Step transitions at ≤1.5× and keep ribs at 0.5–0.6× the nominal wall so they don't sink.
- Gate position. Push air to a vent — position the gate so the flow front ends at a venting point, not a dead-end rib or boss. Hide the knit line on a non-cosmetic face.
- Mold venting. Typical vent depth is 0.01–0.03 mm, cut shallower on LSR (flashes through ~5 µm gaps). Plan vacuum-assisted venting for deep or trapped features.
- Draft angles. Add 1°–3° on vertical faces. Use 3°+ on deep cavities, tall ribs and textured surfaces. Flexible silicone can release many undercuts without a side action — if draft and geometry are planned for it.
- Undercuts & parting lines. Decide the parting-line placement early; specify where the flash line can sit on a cosmetic surface.
- Tolerances. Use generous tolerances where you can. Standard linear tolerance ±0.1–0.3 mm (size-dependent); mold cavities are machined to ±0.008 mm. Reference ISO 3302-1.
- Shrinkage & warpage. LSR shrinks 2.5%–3.5%, HCR 2.0%–3.0% by volume. The cavity is cut larger by the shrinkage factor; getting this wrong is why a first-article part measures out of spec.
- Overmolding. State the substrate material, surface treatment and bonding surface. Self-adhesive LSR bonds via silane coupling agents (no primer); ordinary LSR needs primer or plasma. Keep substrate withstand temperature 140–180 °C in mind.
- Fillets & radii. Add generous radii at sharp corners to reduce stress concentration and tearing on demold.
- First-article trial. T1 first shot — check fill, venting, knit lines and flash; confirm geometry against the drawing, then a dimensional report before release to production.
2 · Quick-reference numbers
| Parameter | LSR (liquid) | Solid silicone (HCR) |
|---|---|---|
| Min / comfortable wall | 0.25–0.5 mm / 0.5–3 mm | Thicker sections |
| Volumetric shrinkage | 2.5%–3.5% | 2.0%–3.0% |
| Flash gap | Flashes through ~5 µm gaps | Higher viscosity, larger gap |
| Vent depth | 0.01–0.03 mm (shallower on LSR) | |
| Draft | 1°–3° vertical faces; 3°+ deep cavities / textured | |
| Standard tolerance | ±0.1–0.3 mm · mold cavities ±0.008 mm · ISO 3302-1 | |
This checklist summarizes the full DFM design guide. Every DFM review at CYES is a written deliverable — a manufacturability report with risk and cost notes, not a phone call. Send your drawing and get a report back within 24 hours.