Compression set is the single most important durability metric for a silicone seal, gasket or O-ring. It measures how much the part fails to recover after being squeezed — and when it fails to recover, the seal leaks. ASTM D395 is the standard test, and this guide explains how it works and what to specify.
What compression set measures
A part is compressed to a set thickness, held for a defined time at a defined temperature, then released. The compression set is the percentage of the original compression that does not recover:
Compression set % = (original thickness − recovered thickness) ÷ (original thickness − compressed thickness) × 100
A value of 0% means full recovery; 100% means the part stayed fully squashed. Lower is better for anything that must keep sealing.
ASTM D395 Method A vs Method B
- Method A — constant force: a fixed load is applied. Used less often for seals.
- Method B — constant deflection: the part is compressed to a fixed strain (usually 25%) for the duration. This is the standard for O-rings and gaskets.
Test conditions that matter
The result is meaningless without the conditions, so always state them. Typical conditions are 22 h, 70 h or 168 h at 23 °C, 70 °C, 100 °C, 125 °C, 150 °C, 175 °C or 200 °C. A number run at 23 °C cannot be compared with one run at 150 °C — higher temperature always makes recovery worse.
Typical silicone compression set values
| Compound | Compression set (Method B, 22 h @ 100 °C) |
|---|---|
| Platinum-cured LSR | 5–15% |
| Peroxide-cured HCR | 15–25% |
| FVMQ (fluorosilicone) | 10–20% |
Why platinum cure wins on compression set
Platinum-catalyzed addition cure cross-links the network more completely and leaves essentially no reaction by-products. The result is a denser, cleaner network that springs back after load. Peroxide cure leaves acidic by-products and a less complete network, so its recovery — and therefore its compression set — is worse. This is exactly why medical and precision seals are specified platinum-cured.
How to spec compression set on your drawing
Don't just write "low compression set". Write something like:
Compression set ≤ 15%, ASTM D395 Method B, 25% deflection, 22 h @ 100 °C
That single line tells the factory exactly which test to run and what bar to clear — and it is the line we verify on first-article and batch testing.
FAQ
What is a good compression set for silicone? For a sealing application, ≤15% is good (platinum-cured), and ≤10% is excellent. Peroxide-cured HCR typically runs 15–25%.
What is the difference between ASTM D395 Method A and B? Method A applies a constant force; Method B applies a constant deflection (typically 25%). Method B is the more common and more repeatable for seals.
Does hardness affect compression set? Generally yes — higher-durometer compounds usually show lower compression set because the denser network recovers better. But cure system matters more than hardness.
Why does peroxide-cured silicone have higher compression set? Peroxide cure leaves residual by-products and a less complete network; platinum cure cross-links more fully and cleanly, so it recovers better after load.