An open (hot) runner cures the runner along with the part, so the runner is scrap; a cold runner keeps the runner channel cool so the material stays uncured and reusable, cutting waste to near zero. Cold runners cost far more in tooling but pay back on material and cycle time at higher volume.
The difference
Because LSR cures with heat, a conventional open runner system cures the entire runner, and that cured runner is thrown away every shot. A cold-runner system actively cools the runner channels so the LSR inside them never cures — only the part in the heated cavity cures. The uncured material is then pushed into the next shot.
The economics
| Attribute | Open runner | Cold runner |
|---|---|---|
| Tool cost | Lower | Much higher |
| Material waste | 20–50% | < 2% |
| Cycle time | Slower (cures runner) | Faster |
| Best for | Low volume, cheap compounds | High volume, expensive LSR |
The break-even is usually around a few tens of thousands of parts — above that, the material savings and faster cycle pay for the cold runner. For expensive medical-grade LSR, a cold runner can pay back even earlier.