For silicone sold into Germany and the EU, LFGB is the compliance bar — and it is a higher bar than FDA. The reason is a single clause most suppliers never mention: the sensory test. This guide decodes §30 and §31 so you know exactly what your silicone is being tested for.

LFGB §30/31 migration testSimulate contact, measure migration, pass or fail.samplecut piecessimulatefood simulantmeasureextract / ICPcomparevs limitpass /fail§30 = overall migration · §31 = sensory / taste transferThe result is a pass/fail report tied to your exact part.
LFGB §30/31 migration testing simulates contact and measures what leaches out — the pass/fail behind EU food-contact silicone.

What LFGB §30 and §31 require

LFGB (the German Food and Feed Code) regulates food-contact materials including silicone. The two key clauses are:

  • §30 — chemical migration: the article must not transfer substances to food in amounts that endanger health.
  • §31 — sensory non-impairment: the article must not change the odor, taste or color of food.

The test battery

TestWhat it measuresTypical limit
Overall migrationTotal non-volatile transfer≤10 mg/dm²
Sensory test (DIN 10955)Odor and taste transferNo impairment
Volatile organics (VOC)Low-molecular-weight siloxanes (D3–D6)≤0.5% by weight
Heavy metalsPb, Cd and othersPer BfR / EU limits

Why silicone fails the sensory test

The most common LFGB failure is residual siloxane oligomers and processing aids. Even below chemical migration limits, these low-molecular-weight compounds carry a detectable taste or odor that a trained sensory panel flags under §31. The fix is a fully cured platinum-cured compound and, where needed, a post-cure to drive off volatiles.

BfR Recommendation XV

The technical basis for silicone is BfR Recommendation XV, the German positive list for silicones. It names the permitted polymers, cross-linking agents and additives, and their conditions of use. A compliant silicone must be built only from ingredients on this list.

LFGB vs FDA

FDA 21 CFR 177.2600 sets extractable limits but has no sensory requirement. LFGB adds the mandatory sensory test, which is why a silicone can pass FDA and still fail LFGB — and why German and EU buyers routinely ask for LFGB instead of, or in addition to, FDA.

How to spec LFGB-compliant silicone

State §30 and §31 (or full BfR Recommendation XV), the intended use temperature, and whether the part is baked, microwaved or cold-contact. The test conditions — food simulants, temperature and time — are set to match the real use, so a part tested at 40 °C is not compliant for 175 °C baking.

FAQ

What do LFGB §30 and §31 cover? §30 governs chemical migration — a material must not release harmful substances into food; §31 governs the sensory test — it must not change the odor, taste or color of food.

Why is the sensory test the hard part for silicone? Silicone can pass all chemical migration limits yet still fail §31 because residual siloxane oligomers or processing aids leave a detectable taste or odor that a trained panel picks up.

What is the VOC limit for silicone? Under BfR guidance, volatile organic compounds (low-molecular-weight siloxanes such as D3–D6 cyclics) are typically limited to 0.5% by weight — poor cure or low-grade stock pushes this over.

How is LFGB different from FDA? LFGB adds a mandatory sensory test that FDA 21 CFR 177.2600 does not require. A silicone can pass every FDA extraction limit and still fail LFGB on taste or odor.