============================================================================== CYES SILICONE - EDITORIAL DATA PACK Cpk, Reported Honestly: An In-House Process Capability Dataset (2026) Version 1.0 | 22 November 2026 | License: CC BY 4.0 ============================================================================== WHAT THIS IS A ready-to-use data attachment for editors, journalists and analysts covering silicone molding tolerances, process capability (Cpk) and supplier verification. Everything here is transcribed from the public CSV and the published landing page. No new data was collected and no value was extrapolated. READ THIS BEFORE QUOTING These are single-factory in-house measurements from CYES SILICONE production lines in Dongguan, China (April-October 2026). They are NOT an industry benchmark, industry average, or a survey of other manufacturers. Blank CSV cells mean "not released (NDA)" - not zero and not "passed". Please keep this scope attached to any figure you reproduce. ------------------------------------------------------------------------------ SEVEN QUOTE-READY FACTS (each carries its full scope) ------------------------------------------------------------------------------ 1. Five desensitized in-house Cpk studies are published as a five-study summary CSV, measured 1.24, 1.27, 1.32, 1.34 and 1.68 against the common 1.33 target. The CSV holds study-level results, not raw per-piece measurements, which are released under NDA. 2. Three of five studies (1.24, 1.27, 1.32) sit below 1.33 and are published as measured - no rounding up, no omission. 3. Two studies (1.34, 1.68) sit above 1.33; LSR-MED-018 also reports Cp 1.74 at n=125. 4. Published sample sizes are n=100 (LSR-MED-007), n=50 (FVMQ-SEAL-010), n=125 (LSR-MED-018), n=80 (LSR-MED-011) and n=70 (HTV-GASKET-014); all five studies carry a published sample size. 5. The long-term pooled Cpk reported across our capability program is 1.27, with a continuous 10-batch SPC trace. 6. Measurement-system MPE is <= (3+L/200) um in X/Y and <= (5+L/200) um in Z (L in mm) at 20 +/-2 degC - instrument capability, not part tolerance. 7. The dataset covers April-October 2026, one factory in Dongguan, China, and is released as v1.0 under CC BY 4.0. Single-factory data, not an industry benchmark. ------------------------------------------------------------------------------ THE FIVE STUDIES (UTF-8 CSV, 11 fields, identical to the public data file) ------------------------------------------------------------------------------ study_reference,product,process,measured_characteristic,specification,sample_size_n,cpk,cp,measurement_equipment,test_date,status_vs_1_33_target LSR-MED-007,Medical LSR diaphragm seal,LSR injection molding (cold-runner),Inner diameter (seal lip),8.00 mm +/-0.02 mm,100,1.24,,Optical measurement (non-contact),2026-04-16,Below target - reported honestly FVMQ-SEAL-010,FVMQ turbocharger static seal,Fluorosilicone (FVMQ) molding,Seal lip thickness,1.20 mm +/-0.05 mm,50,1.32,,Under NDA - validation report,2026-08-20,Below target - reported honestly LSR-MED-018,Medical LSR component,Liquid silicone injection molding,Dimension / hardness / visual,Customer specification,125,1.68,1.74,Under NDA - validation report,2026-10-14,Above target (PASS) LSR-MED-011,Medical LSR valve diaphragm,LSR injection molding,Critical orifice diameter,Customer specification,80,1.27,1.29,,2026-06-11,Below target - reported honestly HTV-GASKET-014,HTV solid-silicone compression gasket,Solid silicone compression molding,Nominal wall,2.00 mm,70,1.34,1.38,,2026-09-15,Above target (PASS) Cpk values: 1.24, 1.32, 1.68, 1.27, 1.34. Three (1.24, 1.27, 1.32) are below the common 1.33 target and are published unchanged. LSR-MED-018 also records Cp 1.74 at n=125. ------------------------------------------------------------------------------ MEASUREMENT SYSTEM (for methodology boxes) ------------------------------------------------------------------------------ In-house desensitized process-capability studies on production silicone parts. Dimensions measured by non-contact optical measurement and calibrated dimensional inspection at 20 +/-2 degC; measurement-system MPE <= (3 + L/200) um in X/Y and <= (5 + L/200) um in Z (L in mm). Cpk and Cp computed from measured production samples (n = 50-125, published per study). Cpk = min[(USL - mu) / 3sigma, (mu - LSL) / 3sigma]; Cp = (USL - LSL) / 6sigma. MPE <= (3+L/200) um in X/Y and <= (5+L/200) um in Z (L in mm), 20 +/-2 degC. Note: +/-0.008 mm is mold-cavity machining accuracy on steel, NOT a molded part tolerance. General molded silicone parts hold +/-0.1-0.3 mm. ------------------------------------------------------------------------------ SUGGESTED CHART / FIGURE ------------------------------------------------------------------------------ Bar chart of five Cpk values against a horizontal 1.33 reference line; label the three below-target bars explicitly. Caption must state "single-factory in-house measurements, CYES SILICONE, 2026; CC BY 4.0". ------------------------------------------------------------------------------ LIMITATIONS (reproduce alongside any figure) ------------------------------------------------------------------------------ - Single factory: all records come from CYES SILICONE's own production lines in Dongguan, China. This is not an industry benchmark, industry average, or survey of other manufacturers. - Time window: studies with published dates run from 2026-04-16 to 2026-10-14; all five studies have a published test date. - NDA constraints: customer identifiers and some validation details are withheld; blank CSV cells mean "not released", not zero and not "passed". - Sample size: all five studies have a published n (50-125); no confidence interval is offered because per-piece raw data remain under NDA. - Assumptions: Cpk assumes an approximately normal, statistically stable process; a value below target is a signal to investigate, not a prediction of defect rate for a different part. - Conditions: measurements were taken under the stated temperature and equipment conditions; results are not transferable to a different measurement system without re-verification. ------------------------------------------------------------------------------ HOW TO CITE (ready-made, CC BY 4.0 requires attribution) ------------------------------------------------------------------------------ CYES SILICONE (2026). Cpk, Reported Honestly: An In-House Process Capability Dataset, v1.0. CYES SILICONE, Dongguan, China. https://www.cyesltd.com/research/cpk-process-capability-report-2026.html. Dataset: https://www.cyesltd.com/data/cpk-process-capability-studies.csv. License: CC BY 4.0 (attribution required). Single-factory in-house measurements; not an industry benchmark. Accessed YYYY-MM-DD. ------------------------------------------------------------------------------ STABLE URLS ------------------------------------------------------------------------------ Landing page (cite this): https://www.cyesltd.com/research/cpk-process-capability-report-2026.html Source dataset CSV: https://www.cyesltd.com/data/cpk-process-capability-studies.csv Whitepaper PDF (v1.0): https://www.cyesltd.com/assets/docs/cyes-cpk-whitepaper-2026-v1.0.pdf This editorial data pack: https://www.cyesltd.com/assets/docs/cyes-cpk-editorial-data-pack-v1.0.txt License: https://creativecommons.org/licenses/by/4.0/ ------------------------------------------------------------------------------ LICENSE & ATTRIBUTION ------------------------------------------------------------------------------ CC BY 4.0. You may share and adapt, including commercially, provided you give appropriate credit to CYES SILICONE, link the license, and indicate if changes were made. No permission request is needed for attribution-only reuse. Please do not present the figures as an industry benchmark. ------------------------------------------------------------------------------ CONTACT (for the underlying validation reports / a study on your part) ------------------------------------------------------------------------------ CYES SILICONE | Dongguan, Guangdong, China | est. 2004 robin@cyesltd.com | +86 180 0288 5787 | https://www.cyesltd.com/get-a-quote.html Sensitive validation documents are provided under NDA. ============================================================================== End of editorial data pack - v1.0 - 22 November 2026 ==============================================================================